Recurrent visual field progression occurred in 167 of 635 eligible eyes (26.3%) following an initial confirmed progression event in a retrospective glaucoma cohort, with faster previous visual field loss and higher subsequent intraocular pressure (IOP) associated with greater recurrence risk. Greater pressure reduction was associated with a lower hazard of recurrence, although some eyes continued to deteriorate despite relatively low pressure levels.
In the study, published in JAMA Ophthalmology, researchers examined clinical data from the Bascom Palmer Ophthalmic Registry collected between 1998 and 2025. The study included 7,457 eyes from 5,086 patients with open-angle glaucoma or suspected glaucoma who underwent at least 8 reliable 24-2 standard automated perimetry examinations over a minimum of 2 years. Mean follow-up was 12.4 years. Eyes were excluded if their mean deviation (MD), averaged across the first 2 visual field examinations, was −18 dB or worse, or if they had ocular conditions that could confound visual field interpretation. Visual field progression was assessed using Guided Progression Analysis (GPA), which defined likely progression as statistically significant deterioration at 3 or more corresponding test locations across 3 consecutive examinations.
The primary outcomes were the cumulative probability of recurrent visual field progression and factors associated with recurrence. Following an initial GPA likely-progression event, the authors established new visual field baselines using the first progressing examination and the subsequent examination, then reapplied GPA to later examinations. Kaplan-Meier methods were used to estimate cumulative recurrence, while Cox proportional hazards models assessed associations with demographic characteristics, visual field measurements, and IOP. Additional analyses evaluated previous rates of visual field loss and the magnitude of IOP reduction following initial progression.
Initial likely progression occurred in 1,951 eyes (26.2%). Of these, 635 had sufficient subsequent visual field examinations and IOP measurements for recurrence analysis. Recurrent progression occurred in 167 eyes (26.3%), with cumulative probabilities of 13.8% at 3 years, 25.6% at 5 years, and 43.5% at 10 years. The mean interval between the initial and recurrent progression events was 3.2 years.
Faster visual field loss prior to the initial progression event was independently associated with recurrence. Each additional 1 dB/year of MD loss corresponded to a 73% higher hazard of recurrent progression. Among eyes with previous MD slopes faster than −1 dB/year, recurrence occurred in 42.7%, compared with 23.4% among eyes with slower progression.
Higher IOP following initial progression was also independently associated with recurrence. Each 1 mmHg increase in mean post-event IOP corresponded to a 9% higher recurrence hazard. Eyes with mean post-event IOP greater than 18 mmHg had a recurrence rate of 39.6%, compared with 24.1% among eyes with IOP of 18 mmHg or lower. Mean post-event IOP was 15.4 mmHg among eyes with recurrence and 14.1 mmHg among those without recurrence.
Greater IOP reduction following the first progression event was associated with lower recurrence risk. Each additional 10% reduction in IOP corresponded to an 11% lower hazard of recurrence. Because mean post-event IOP and percentage IOP reduction were correlated, the authors evaluated these measures in separate multivariable models.
Subgroup analyses further demonstrated differences among 96 eyes with previous MD slopes faster than -1 dB/year. Within this subgroup, those without recurrence had a lower mean post-event IOP than those with recurrence (14 vs 16.2 mmHg). An IOP reduction greater than 20% was also more common among eyes without recurrence than among eyes with recurrence (36.4% vs 12.2%). The annual rate of MD loss slowed from −1.71 to −0.39 dB/year among eyes without recurrence, compared with −1.70 to −1.31 dB/year among eyes with recurrence. Total MD loss following the initial progression event was also greater among eyes with recurrence (−7.31 vs −1.78 dB).
Older age and less severe visual field loss at initial progression, reflected by a less negative MD, were independently associated with recurrence. Each additional 5 years of age corresponded to an 11% higher recurrence hazard, while each 1-dB increase in MD at first progression corresponded to an 8% higher hazard. Association with less advanced damage may partly reflect reduced sensitivity of event-based progression analysis in eyes with more severe visual field loss.
Sex, race, central corneal thickness, and the spatial distribution of the initial progression event showed no statistically significant associations with recurrence in the reported analyses. IOP measurements prior to the first progression event also showed no statistically significant association with subsequent recurrence.
The study had several limitations. Data were obtained from a single tertiary academic center, potentially limiting generalizability. Information on medication changes, laser or surgical interventions, and treatment adherence was unavailable, preventing investigators from determining which interventions contributed to observed IOP reductions. The requirement for repeated reliable visual field examinations may have selected eyes undergoing more frequent monitoring, while the reduction from 1,951 initially progressing eyes to 635 eligible for recurrence analysis introduced potential selection bias. Recurrence was detected in 26.3% of the analytic sample vs 15.2% of the broader progressing cohort, a difference the authors suggested may reflect ascertainment bias because detecting recurrent progression required sufficient follow-up examinations. Event-based progression analysis may also underestimate deterioration in advanced glaucoma. Additionally, fewer eyes remained at risk during extended follow-up, with only 30 eyes remaining at 10 years, reducing the precision of long-term recurrence estimates.
According to the authors, an initial confirmed progression event may help identify eyes requiring closer monitoring, particularly those with faster previous visual field deterioration or higher subsequent IOP. As an observational study, the analysis could not establish causation. "However, recurrence despite IOP in the low to mid-teens underscores the limits of pressure lowering alone and supports complementary neuroprotective approaches," wrote lead study author Davina A. Malek, MD, of the Bascom Palmer Eye Institute, University of Miami, Miami, Florida, and colleagues.
Disclosures: Dr da Costa reported personal fees from Vöiston AI; Dr Scherer reported equity, patent interests, and consulting relationships; and Dr Medeiros reported research grants and consulting fees. No other disclosures were reported.
Source: JAMA Ophthalmology